Huge thanks to our Platinum Members Endace and LiveAction,
and our Silver Member Veeam, for supporting the Wireshark Foundation and project.

Wireshark-bugs: [Wireshark-bugs] [Bug 8299] New: Capture Options dialog interfaces do not displa

Date: Tue, 05 Feb 2013 04:57:36 +0000
Bug ID 8299
Summary Capture Options dialog interfaces do not display properly
Classification Unclassified
Product Wireshark
Version 1.9.x (Experimental)
Hardware x86
OS Windows Vista
Status UNCONFIRMED
Severity Normal
Priority Low
Component Wireshark
Assignee [email protected]
Reporter [email protected]

Created attachment 9931 [details]
Screen Shot of Capture Options dialog on Windows Vista

Build Information:
Version 1.9.0-SVN-47482 (SVN Rev 47482 from /trunk)

Copyright 1998-2013 Gerald Combs <[email protected]> and contributors.
This is free software; see the source for copying conditions. There is NO
warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

Compiled (32-bit) with GTK+ 2.24.14, with Cairo 1.10.2, with Pango 1.30.1, with
GLib 2.34.1, with WinPcap (4_1_2), with libz 1.2.5, without POSIX capabilities,
without libnl, with SMI 0.4.8, with c-ares 1.7.1, with Lua 5.1, without Python,
with GnuTLS 2.12.18, with Gcrypt 1.4.6, with MIT Kerberos, with GeoIP, with
PortAudio V19-devel (built Feb  4 2013), with AirPcap.

Running on 32-bit Windows Vista Service Pack 2, build 6002, with WinPcap
version
4.1.2 (packet.dll version 4.1.0.2001), based on libpcap version 1.0 branch
1_0_rel0b (20091008), GnuTLS 2.12.18, Gcrypt 1.4.6, with AirPcap 4.1.1 build
1838.
AMD Athlon(tm) 64 X2 Dual Core Processor 4000+, with 1917MB of physical memory.


Built using Microsoft Visual C++ 10.0 build 40219
--
In Version 1.9.0-SVN-47482 running on Windows Vista, the interface list on the
Capture Options dialog shows only the "Capture" and "Interface" columns. The
"Link layer header," "Prom. Mode," "Snaplen [B]," "Buffer [MB]," and "Capture
Filter" columns are missing. See the attached screen shot. The PortableApps
version running on the same PC shows the same display.

1.9.0-SVN-47482 running on Windows 7 Professional 64-bit shows only the
"Capture" column with the check boxes to select interfaces for capturing. All
other columns are missing, including the interface names. See the second
attached screen shot.


You are receiving this mail because: