ANNOUNCEMENT: Live Wireshark University & Allegro Packets online APAC Wireshark Training Session
July 17th, 2024 | 10:00am-11:55am SGT (UTC+8) | Online

Display Filter Reference: ZigBee ZCL Pump Configuration and Control

Protocol field name: zbee_zcl_hvac.pump_config_ctrl

Versions: 2.2.0 to 4.2.5

Back to Display Filter Reference

Field name Description Type Versions
zbee_zcl_hvac.pump_config_control.attr.alarmAlarm MaskUnsigned integer (16 bits)2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.dry_runningDry runningBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.elec_fatal_failElectronic fatal failureBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.elec_non_fatal_failElectronic non-fatal failureBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.elec_temp_too_highElectronic temperature too highBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.gen_faultGeneral faultBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.mtr_fatal_failPump motor has fatal failureBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.mtr_temp_too_highMotor temperature too highBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.press_too_highSystem pressure too highBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.press_too_lowSystem pressure too lowBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.pump_blockPump blockedBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.pwr_missing_phasePower missing phaseBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.sensor_failSensor failureBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.volt_too_highSupply voltage too highBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.alarm.volt_too_lowSupply voltage too lowBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.ctrl_modeEffective Control ModeUnsigned integer (8 bits)2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.effective_opr_modeEffective Operation ModeUnsigned integer (8 bits)2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.opr_modeOperation ModeUnsigned integer (8 bits)2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.statusPump StatusUnsigned integer (16 bits)2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.status.device_faultDevice FaultBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.status.local_overrideLocal OverrideBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.status.rem_flowRemote FlowBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.status.rem_pressureRemote PressureBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.status.rem_tempRemote TemperatureBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.status.runningRunningBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.status.speed_highSpeed HighBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.status.speed_lowSpeed LowBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr.status.supply_faultSupply FaultBoolean2.2.0 to 4.2.5
zbee_zcl_hvac.pump_config_control.attr_idAttributeUnsigned integer (16 bits)2.2.0 to 4.2.5