Huge thanks to our Platinum Members Endace and LiveAction,
and our Silver Member Veeam, for supporting the Wireshark Foundation and project.

Wireshark-users: Re: [Wireshark-users] Nettl HP-UX

From: Guy Harris <guy@xxxxxxxxxxxx>
Date: Tue, 28 Jun 2011 14:46:34 -0700
On Jun 28, 2011, at 1:57 PM, Chris Maynard wrote:

> Guy Harris <guy@...> writes:
> 
>> maxValidFrame is 1500.  (And, yes, this means that values of the length/type
> field between 1501 and 1535
>> are, apparently, illegal.)
> 
> So how should Wireshark handle such invalid frames?

Good question.

> As a simple test, I
> manually modified an IEEE 802.3 Ethernet packet and changed its length from 38
> bytes (with 8 bytes of trailer) to 1501 bytes.  Wireshark displayed it as an
> Ethernet II frame of "Type: unknown (0x05dd)" and payload of 46 bytes.

Yes, the code currently treats all type/length field values < IEEE_802_3_MAX_LEN=1500 as type field values.

> But if 1501-1535 are invalid, maybe at the very least an Expert Info should be added to
> report it?

Yes.

My copy of version 1 of the DEC/Intel/Xerox Ethernet spec doesn't say anything about valid type field values, unless I missed it.  Perhaps version 2 does; in any case, perhaps we should dissect frames with type/length fields in that range as invalid rather than as having a type *or* length field.