Huge thanks to our Platinum Members Endace and LiveAction,
and our Silver Member Veeam, for supporting the Wireshark Foundation and project.

Wireshark-commits: [Wireshark-commits] rev 40133: /trunk/epan/dissectors/ /trunk/epan/dissectors/:

Date: Fri, 09 Dec 2011 17:00:28 GMT
http://anonsvn.wireshark.org/viewvc/viewvc.cgi?view=rev&revision=40133

User: alagoutte
Date: 2011/12/09 09:00 AM

Log:
 From report of Arasch Honarbacht via https://bugs.wireshark.org/bugzilla/show_bug.cgi?id=6649
 ZigBee ZCL Dissector reports invalid status
 
 The status code 0x8d contained in an attriute status record in a configure reporting response frame is incorrectly displayed as "Write only" (where WRITE_ONLY = 0x8f). According to the ZigBee Cluster Library Specification, Document 075123r03ZB, April 26, 2010 a status of 0x8d should display as "INVALID_DATA_TYPE"
 
 From me :
 Fix this issue (Wrong value define) based on Specs available in ZigBee.org

Directory: /trunk/epan/dissectors/
  Changes    Path                 Action
  +2 -3      packet-zbee-zcl.c    Modified
  +15 -16    packet-zbee-zcl.h    Modified