Wireshark-bugs: [Wireshark-bugs] [Bug 7263] cflow.timeend >= cflow.sysuptime - Option to compare

Date: Thu, 24 Oct 2013 20:53:27 +0000

Comment # 7 on bug 7263 from
(In reply to comment #6)
> Hello,
> 
> (In reply to comment #5)
> > I think only allowing comparison of fields of the same time is reasonable. 
> > And we have it for some time now.  Closing this one...
> 
> Right now I don't have any wireshark installed and can't test, but
> I think comment #2 is still valid.
> 
> (Just looking at current sources cflow.timeend is FT_RELATIVE_TIME, and
> cflow.sysuptime is FT_UINT32)

Sure but...  Oh, OK, I see, the request in this bug is the same as what is
described in comment #2.  So while comparing fields has been added, comparing
the fields requested here is not.

OK, so I checked in a simple solution (only for this field) in r52821 : I made
cflow.sysuptime an FT_RELATIVE_TIME.  So instead of showing the user
milliseconds we show them seconds (I don't imagine anyone will care) and it
allows comparison with the timend field.


You are receiving this mail because:
  • You are watching all bug changes.