Display Filter Reference: RLC-NR

Protocol field name: rlc-nr

Versions: 2.6.0 to 2.6.5

Back to Display Filter Reference

Field name Description Type Versions
rlc-nr.am AM Character string 2.6.0 to 2.6.5
rlc-nr.am-data.no-data AM data PDU doesn\'t contain any data Label 2.6.0 to 2.6.5
rlc-nr.am.ack-sn ACK Sequence Number Unsigned integer, 3 bytes 2.6.0 to 2.6.5
rlc-nr.am.cpt Control PDU Type Unsigned integer, 1 byte 2.6.0 to 2.6.5
rlc-nr.am.cpt.invalid RLC Control frame type not handled Label 2.6.0 to 2.6.5
rlc-nr.am.data AM Data Sequence of bytes 2.6.0 to 2.6.5
rlc-nr.am.dc Data/Control Boolean 2.6.0 to 2.6.5
rlc-nr.am.e1 Extension bit 1 Boolean 2.6.0 to 2.6.5
rlc-nr.am.e2 Extension bit 2 Boolean 2.6.0 to 2.6.5
rlc-nr.am.e3 Extension bit 3 Boolean 2.6.0 to 2.6.5
rlc-nr.am.header AM Header Character string 2.6.0 to 2.6.5
rlc-nr.am.nack-range NACK range Unsigned integer, 2 bytes 2.6.0 to 2.6.5
rlc-nr.am.nack-sn NACK Sequence Number Unsigned integer, 3 bytes 2.6.0 to 2.6.5
rlc-nr.am.nack-sn.ack-same Status PDU shouldn\'t ACK and NACK the same sequence number Label 2.6.0 to 2.6.5
rlc-nr.am.nack-sn.ahead-ack NACK must not be ahead of ACK in status PDU Label 2.6.0 to 2.6.5
rlc-nr.am.nack-sn.expert Status PDU reports NACK Label 2.6.0 to 2.6.5
rlc-nr.am.nack-sn.nack-range Status PDU shouldnot contain a NACK range vith value 0 Label 2.6.0 to 2.6.5
rlc-nr.am.nack-sn.partial Status PDU reports NACK (partial) Label 2.6.0 to 2.6.5
rlc-nr.am.nacks Number of NACKs Unsigned integer, 4 bytes 2.6.0 to 2.6.5
rlc-nr.am.p Polling Bit Boolean 2.6.0 to 2.6.5
rlc-nr.am.reserved Reserved Unsigned integer, 1 byte 2.6.0 to 2.6.5
rlc-nr.am.si Segmentation Info Unsigned integer, 1 byte 2.6.0 to 2.6.5
rlc-nr.am.sn Sequence Number Unsigned integer, 2 bytes 2.6.0 to 2.6.5
rlc-nr.am.sn.invalid Invalid sequence number length Label 2.6.0 to 2.6.5
rlc-nr.am.so Segment Offset Unsigned integer, 2 bytes 2.6.0 to 2.6.5
rlc-nr.am.so-end SO end Unsigned integer, 2 bytes 2.6.0 to 2.6.5
rlc-nr.am.so-start SO start Unsigned integer, 2 bytes 2.6.0 to 2.6.5
rlc-nr.bearer-id Bearer Id Unsigned integer, 2 bytes 2.6.0 to 2.6.5
rlc-nr.bearer-type Bearer Type Unsigned integer, 2 bytes 2.6.0 to 2.6.5
rlc-nr.bytes-after-status-pdu-complete bytes remaining after Status PDU complete Label 2.6.0 to 2.6.5
rlc-nr.context Context Character string 2.6.0 to 2.6.5
rlc-nr.direction Direction Unsigned integer, 1 byte 2.6.0 to 2.6.5
rlc-nr.header-only RLC PDU Header only Boolean 2.6.0 to 2.6.5
rlc-nr.header-only.expert RLC PDU SDUs have been omitted Label 2.6.0 to 2.6.5
rlc-nr.mode RLC Mode Unsigned integer, 1 byte 2.6.0 to 2.6.5
rlc-nr.mode.invalid Unrecognised RLC Mode set Label 2.6.0 to 2.6.5
rlc-nr.no_per_frame_info Can\'t dissect NR RLC frame because no per-frame info was attached! Label 2.6.0 to 2.6.5
rlc-nr.pdu-length PDU Length Unsigned integer, 2 bytes 2.6.0 to 2.6.5
rlc-nr.reserved-bits-not-zero Reserved bits not zero Label 2.6.0 to 2.6.5
rlc-nr.seqnum-length Sequence Number length Unsigned integer, 1 byte 2.6.0 to 2.6.5
rlc-nr.tm TM Character string 2.6.0 to 2.6.5
rlc-nr.tm.data TM Data Sequence of bytes 2.6.0 to 2.6.5
rlc-nr.ueid UEId Unsigned integer, 2 bytes 2.6.0 to 2.6.5
rlc-nr.um UM Character string 2.6.0 to 2.6.5
rlc-nr.um-data.no-data UM data PDU doesn\'t contain any data Label 2.6.0 to 2.6.5
rlc-nr.um.data UM Data Sequence of bytes 2.6.0 to 2.6.5
rlc-nr.um.header UM Header Character string 2.6.0 to 2.6.5
rlc-nr.um.reserved Reserved Unsigned integer, 1 byte 2.6.0 to 2.6.5
rlc-nr.um.si Segmentation Info Unsigned integer, 1 byte 2.6.0 to 2.6.5
rlc-nr.um.sn Sequence Number Unsigned integer, 1 byte 2.6.0 to 2.6.5
rlc-nr.um.sn.invalid Invalid sequence number length Label 2.6.0 to 2.6.5
rlc-nr.um.so Segment Offset Unsigned integer, 2 bytes 2.6.0 to 2.6.5
Go Beyond with Riverbed Technology

Riverbed is Wireshark's primary sponsor and provides our funding. They also make great products that fully integrate with Wireshark.

I have a lot of traffic...

ANSWER: SteelCentral™ Packet Analyzer PE
  • • Visually rich, powerful LAN analyzer
  • • Quickly access very large pcap files
  • • Professional, customizable reports
  • • Advanced triggers and alerts
Learn More

Buy Now

No, really, I have a LOT of traffic…

ANSWER: SteelCentral™ AppResponse 11
  • • Full stack analysis – from packets to pages
  • • Rich performance metrics & pre-defined insights for fast problem identification/resolution
  • • Modular, flexible solution for deeply-analyzing network & application performance
Learn More